Validation against BRAS

Auralis is checked against BRAS, the Benchmark for Room Acoustical Simulation from TU Berlin. BRAS has measured impulse responses, room models and measured material data for a set of scenes. Its data is free (CC BY-SA 4.0).

The rules

  • No fitting to the target. Materials come from the BRAS material data and documents. They are never tuned to get closer to the measured responses.

  • Report the strict reading too. When a metric can be read in a kind way and a strict way, both are published.

  • Keep negative results. What does not work is written down in the project history.

Rooms (CR scenes)

Each room result is the mean error over the source and receiver pairs and the octave bands, in just noticeable differences (JND):

Parameter

One JND

T30

5 %

C50

1 dB

Ts

10 ms

Level per band

1 dB

A value of 1 JND means the error is just at the limit of what a listener can hear. The parameters are computed on the omnidirectional response, like the omni microphone of BRAS, in true octave bands.

Scene

Room

Mean error

Share within 1 JND

CR2

Seminar room

1.09 JND

67 %

CR3

Chamber music hall

1.51 JND

40 %

CR4

Auditorium

1.86 JND

37 %

CR1

Coupled rooms, door at 30.4°

3.01 JND

26 %

CR1

Coupled rooms, door at 4.1°

3.99 JND

18 %

What is known about the remaining errors:

  • CR3 and CR4: the simulated T30 is 10 to 16 % too long between 250 Hz and 2 kHz. The BRAS “fitted” materials were tuned with the Eyring formula, which assumes a diffuse field. With little scattering on the walls, the real decay depends on scattering that the data does not describe. Auralis does not add scattering to hide this.

  • All rooms, 2 kHz: the level is 3 dB too high. The source data sheet and the direct sound of the room sessions do not agree at 2 kHz. Auralis keeps the data sheet.

  • CR1: the coupling between the two rooms is right when the grid resolves it. The low end of the reverberant room is too long, for the same reason as CR3 and CR4.

Scenes with one object (RS scenes)

These scenes have a single condition. The metric is the insertion loss: the response with the object against the free-field response. It removes the response and the directivity of the loudspeaker. Auralis reports the Pearson correlation with the measurement from 160 Hz to 2 kHz, in third-octave bands and raw.

Scene

Content

Insertion loss, third octaves

Raw transfer function

RS7

Rows of seats (seat dip)

0.890

0.766

RS6

A finite body (diffraction)

0.836

0.607

Reflection from a plane (RS1)

RS1 compares a rigid floor with an absorbing floor and with a diffuser. The metric is the correlation of the transfer function differences between two states.

Difference

Correlation

Rigid against absorbing

0.658

Rigid against diffuser

0.511

These numbers come from the published grid settings. A finer grid gives different values (0.54 to 0.68 for the absorber, 0.22 to 0.26 for the diffuser, depending on the wall correction). The finer values are the more reliable ones. The diffuser at high frequencies is still not well reproduced.

Exact references for the geometrical solver

In a box, the geometrical solver is compared with image sources of all orders and with radiosity. C50 and EDT match these exact references to the second decimal.

Reproduce the results

The BRAS data goes in data_bras/. Each scene has a README next to its harness, with the exact commands:

Scene

Harness

CR1 to CR4

BRAS/CR2/cr2_run.py <manifest>

RS1

BRAS/RS1/rs1_reflection.py

RS5, RS6, RS7

BRAS/RS5/run.py, BRAS/RS6/run.py, BRAS/RS7/run.py

For example:

python3 BRAS/CR2/cr2_run.py BRAS/CR2/cr2_dodecahedron_fitted31_dir_omni.json -o out_cr2
python3 BRAS/bras_jnd.py out_cr2/report.csv

The harnesses keep their intermediate results. Running the same command again resumes where it stopped.